VIDMANTAS PUPEIKIS

Data center design & advisory

White space that fits the load, the budget and the building.

Independent, vendor-neutral advice on data center rooms and colocation cages: from the first capacity estimate to a running, documented space. No reseller margins, no preferred brands. Based in Vilnius, working across Europe.

CAGE 01 · 80 RACKS · A/B POWERCOLD AISLEHOT AISLECOLD AISLE20 × 600 mm = 12.0 m rowGPU / high-density row
2012working in data centers since
2MWlargest cage designed, 100 racks
300+racks across 7 data centers in Frankfurt
10network and server cages built and run

Areas of expertise

The full lifecycle of a data center space, from the first capacity estimate to the room running in production. Bring me in for a single test-fit or second opinion, or for the whole project.

aisles · clearances
01

White space design

Floor plans for rooms and colocation cages from 6 to 100 racks: rack positions, hot and cold aisles, clearances, cable routes and room for growth.

  • Rack layouts and elevations
  • Cage layouts in colocation
  • Structured cabling plans
UTILITYGENATSUPS AUPS BRACK2N · A/B feeds · kW per rack
02

Capacity & power planning

Power and capacity models that hold up on day one and at full load. Redundancy topologies, per-rack density and phased growth up to multi-megawatt halls, including GPU and high-density readiness: what your room can carry today and what it needs for the next step up in density.

  • 2N, UPS and generator design
  • GPU and high-density planning
  • Capacity models for 2 MW+
18–27 °C INEXHAUSTairflow · containment · fire & security
03

Cooling & facility systems

Checking that airflow, cooling, fire suppression and physical security fit the IT load you plan to install, and adjusting the design where they do not.

  • Airflow and containment
  • Fire suppression and CCTV
  • Design checks against site limits
powerfibreriskSITE B · SCORE 88
04

Site selection & colocation review

Finding and evaluating new sites, and reviewing colocation providers' proposals so the final space works for both the tenant and the operator.

  • Site search and evaluation
  • Provider layout review and redesign
  • Requirements for RFPs
42414039383736353433323130292827BOM · RACK A07SW-TOR-48P×2PDU 3PH 32A×2SRV 2U×8GPU 4U×2PATCH CAT6A×1
05

Build-out & commissioning

From BOM to live racks. I coordinate vendors, contractors and procurement, oversee installation and commissioning, and adjust the design as the build progresses.

  • Bills of materials
  • Vendor and contractor coordination
  • Server, storage and network deployment
IT LOAD · kW72%capacityUPS OKCRAH OKPDU B
06

Operations & DCIM

Setting up how the room runs day to day: DCIM records, monitoring, incident handling and vendor repairs, plus training the team that takes it over.

  • DCIM: Device42, Nlyte
  • Monitoring: Zabbix, Grafana
  • 24/7 operations and incidents
REVIEW · REV B! PDU B overload! aisle < 1.2 m✓ cooling margin✓ cable routes2 issues found
07

Second opinion & design review

Before you sign a colocation contract or approve a contractor's design, I review the layout, power and cooling assumptions and show where the risks and hidden costs are.

  • Colocation proposal review
  • Contractor design check
  • Risk and cost findings

Why work with me

A single specialist instead of a large firm: direct contact, no handovers between teams.

Hands-on

I have run the rooms I design, so the plans account for how a space is installed, operated and repaired.

Vendor-neutral

Recommendations follow your requirements, not a product line. I do not resell equipment.

One person, start to finish

The person who drew the plan is on site at commissioning and answers for the result.

Selected work

A few projects that show the scale and type of work. Client names and further details on request.

2 MW

100-rack cage design

Designed a 100-rack, 2 MW high-density cage together with a US engineering team, and contributed to planning data centers and labs on the US West Coast.

7 DCs

European infrastructure from day one

Joined a global cybersecurity company's European build-out at its start and worked across 7 data centers in Frankfurt: 10 network and server cages, 300+ racks and 4 labs.

NER

Colocation layout redesign

Reworked the network equipment room layout proposed by a colocation provider into a solution that worked better for both the tenant and the operator.

75 + 6

Enterprise and high-security cages

Ran a 75-rack enterprise cage and a separate high-security 6-rack cage, coordinating 25–30 contacts across OEMs and rack and cabling suppliers.

How a project runs

Every engagement follows the same four stages, with a clear deliverable at the end of each one.

Assess

Current site, IT roadmap, power and cooling limits, budget.

→ capacity model

Design

Floor plan, rack elevations, power and cooling distribution.

→ drawings, BOM

Build

Vendors, contractors and installation, through to commissioning.

→ commissioned space

Operate

DCIM, monitoring, processes and handover to your team.

→ documented operations

Equipment I have deployed and supported

  • APC
  • Cisco
  • Arista
  • F5
  • Dell EMC
  • HPE
  • IBM
  • Lenovo
  • MAN

Tools: Device42, Nlyte, Zabbix, Grafana, AutoCAD.

Languages

  • Englishfluent
  • Lithuaniannative
  • Russianfluent
  • Germanbasic

On-site, hybrid or remote. Available to travel in Lithuania and abroad.

Planning a new room, cage or expansion?

Send a short description of the site, the expected IT load and your timeline. I will reply with how I can help.

vp@vpi.lt